Test Code 0201574 Rubella Antibody, IgG Only, Serum
Methodology
Indirect Chemiluminescence Immunoassay (CLIA)
Performing Laboratory
Alomere Health Hospital Laboratory
Specimen Requirements
Specimen Type: Serum only
Collection Container/Tube: Gold (gel separator) or Red (plain)
Specimen Volume: 1.0 mL
Specimen Minimum Volume: 0.5 mL
Collection Instructions:
1. Allow serum tubes to clot completely. This may take up to 30 minutes.
2. Remove sample from cells by pipetting.
Specimen Transport Temperature
Refrigerated
Reference Values
Reported as Positive, Negative, or Equivocal
Day(s) Test Set Up
Monday - Friday
Test Classification and CPT Coding
86762