Test Code ALB24 Albumin, 24 Hour, Urine
Necessary Information
24-Hour volume (in milliliters) is required.
Specimen Required
Supplies: Sarstedt 5 mL Aliquot Tube (T914)
Container/Tube: Plastic urine tube
Specimen Volume: 4 mL
Collection Instructions:
1. Collect urine for 24 hours.
2. Refrigerate specimen within 4 hours of completion of 24-hour collection.
3. Mix well before taking 4-mL aliquot.
Additional Information: See Urine Preservatives-Collection and Transportation for 24-Hour Urine Specimens for multiple collections.
Useful For
Evaluating diabetic patients to assess the potential for early onset of nephropathy
Special Instructions
Reporting Name
Albumin, 24 Hr, USpecimen Type
UrineSpecimen Minimum Volume
1 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Refrigerated (preferred) | 7 days | |
Ambient | 7 days | ||
Frozen | 7 days |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Clinical Information
Albumin excretion increases in patients with diabetes who are destined to develop diabetic nephropathy. More importantly, at this phase of increased albumin excretion before overt proteinuria develops, therapeutic maneuvers can be expected to significantly delay, or possibly prevent, development of nephropathy. These maneuvers include aggressive blood pressure maintenance (particularly with angiotensin-converting enzyme inhibitors), aggressive blood sugar control, and possibly decreased protein intake. Thus, there is a need for addressing small amounts of urinary albumin excretion (in the range of 30-300 mg/day, ie, microalbuminuria).
The National Kidney Foundation convened an expert panel to recommend guidelines for the management of patients with diabetes and microalbuminuria. These guidelines recommend that all type 1 diabetic patients older than 12 years and all type 2 diabetic patients younger than 70 years should have their urine tested for microalbuminuria yearly when they are under stable glucose control.(1)
The preferred specimen is a 24-hour collection, but a 10-hour overnight collection (9 p.m.-7 a.m.) or a random collection are acceptable. Recent studies have shown that correcting albumin for creatinine excretion rates has similar discriminatory value with respect to diabetic renal involvement, and it is now suggested that an albumin/creatinine ratio from a random urine specimen is a valid screening tool.(2)
Several studies have addressed the question of whether this needs to be a fasting urine, an exercised urine, or an overnight urine specimen. From these studies, it is clear that the first-morning urine specimen is less sensitive, but more specific. A positive result should be confirmed by a first-morning random or 24-hour timed urine specimen.
Studies have also shown that microalbuminuria is a marker of generalized vascular disease and is associated with stroke and heart disease.
Reference Values
24-Hour excretion: <30 mg/24 hours
Excretion rate: <20 mcg/min
Interpretation
An albumin excretion rate of more than 30 mg/24 hours is considered to be microalbuminuric. By definition, the upper end of microalbuminuria is thought to be 300 mg/24 hours. Although this level has not been rigorously defined, it is felt that at this level it is more difficult to change the course of diabetic nephropathy. Laboratory normal values agree with the 30 mg/24 hour level. A normal excretion rate of 20 mcg/minute has also been established in the literature and is consistent with the laboratory data. Thus, microalbuminuria has been defined at 30 to 300 mg/24 hours.
The literature has defined the albumin/creatinine ratio (mg/g) below 17 as normal for males and below 25 for females(2) and is consistent with the laboratory's normal data. A ratio of albumin to creatinine of 300 or more indicates overt albuminuria. Thus, microalbuminuria has been defined as an albumin/creatinine ratio of 17 to 299 for males and 25 to 299 for females.
Due to biologic variability, any patient who has an albumin/creatinine ratio or urinary albumin excretion rate in the positive microalbuminuria range should have this confirmed with a second specimen. If there is discrepancy, a third specimen is recommended. If 2 of 3 results are in the positive microalbuminuria range, this is evidence for incipient nephropathy and warrants increased efforts at glucose control, aggressive blood pressure control, and institution of therapy with an angiotensin-converting enzyme inhibitor (if the patient can tolerate it).
Day(s) Performed
Monday through Sunday
Report Available
Same day/1 to 3 daysSpecimen Retention Time
7 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
82043
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
ALB24 | Albumin, 24 Hr, U | 1755-8 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
AL24H | Albumin, 24 Hr, U | 1755-8 |
TM43 | Collection Duration | 13362-9 |
VL41 | Urine Volume | 3167-4 |
RATE2 | Albumin Excretion Rate | 58448-2 |
Method Name
Immunoturbidity
Forms
If not ordering electronically, complete, print, and send a Renal Diagnostics Test Request (T830) with the specimen.