Test Code CLFA Cryptococcus Antigen Screen with Titer, Spinal Fluid

Useful For

Aiding in the diagnosis of cryptococcosis

 

This test should not be performed as a screening procedure for the general population.

 

This test should not be used as a test of cure or to guide treatment decisions.

Disease States

  • Cryptococcosis

Reflex Tests

Test ID Reporting Name Available Separately Always Performed
CLFAT Cryptococcus Ag Titer, LFA, CSF Yes No

Testing Algorithm

If result is positive, Cryptococcus titer will be performed at an additional charge.

 

For more information see Meningitis/Encephalitis Panel Algorithm

Reporting Name

Cryptococcus Ag Screen w/Titer, CSF

Specimen Type

CSF


Specimen Required


Container/Tube: Sterile vial

Specimen Volume: 1 mL


Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
CSF Refrigerated (preferred) 14 days
  Frozen  14 days

Reject Due To

Gross hemolysis Reject

Clinical Information

Cryptococcosis is an invasive fungal infection caused by Cryptococcus neoformans or Cryptococcus gattii. C neoformans has been isolated from several sites in nature, particularly weathered pigeon droppings. C gattii was previously only associated with tropical and subtropical regions. More recently, however, this organism has been found to be endemic in British Columbia and the Pacific Northwestern United States and is associated with several different tree species.

 

Infection is usually acquired via the pulmonary route. Patients are often unaware of any exposure history. Approximately half of the patients with symptomatic disease have a predisposing immunosuppressive condition such as AIDS, steroid therapy, lymphoma, or sarcoidosis. Symptoms may include fever, headache, dizziness, ataxia, somnolence, and cough. While the majority of C neoformans infections occur in immunocompromised patient populations, C gattii has a higher predilection for infection of healthy individuals.(1,2)

 

In addition to the lungs, cryptococcal infections frequently involve the central nervous system (CNS), particularly in patients infected with HIV. Mortality among patients with CNS cryptococcosis may approach 25% despite antibiotic therapy. Untreated CNS cryptococcosis is invariably fatal. Disseminated disease may affect any organ system and usually occurs in immunosuppressed individuals.

Reference Values

Negative

Reference values apply to all ages.

Interpretation

The presence of cryptococcal antigen in any body fluid (serum or cerebrospinal fluid [CSF]) is indicative of cryptococcosis. Specimens that are positive by the lateral flow assay (LFA) screen are automatically repeated by the same method utilizing dilutions to generate a titer value. CSF specimens submitted for initial diagnosis that test positive by LFA should also be submitted for routine fungal culture. Culture can aid in differentiating between the 2 common Cryptococcus species causing disease (Cryptococcus neoformans and Cryptococcus gattii) and can be used for antifungal susceptibility testing, if necessary. CSF specimens submitted to monitor antigen levels during treatment do not need to be cultured.

 

Disseminated infection is usually accompanied by a positive serum test.

 

Higher Cryptococcus antigen titers appear to correlate with more severe infections. Declining titers may indicate regression of infection. However, monitoring titers to cryptococcal antigen should not be used as a test of cure or to guide treatment decisions. Low-level titers may persist for extended periods of time following appropriate therapy and the resolution of infection.(3)

Day(s) Performed

Monday through Sunday

Report Available

Same day/1 to 2 days

Specimen Retention Time

14 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

87899-Cryptococcus screen

87899-Cryptococcus titer (if appropriate)

LOINC Code Information

Test ID Test Order Name Order LOINC Value
CLFA Cryptococcus Ag Screen w/Titer, CSF 29896-8

 

Result ID Test Result Name Result LOINC Value
62074 Cryptococcus Ag Screen w/Titer, CSF 29896-8

Method Name

Lateral Flow Assay (LFA)

Forms

If not ordering electronically, complete, print, and send Infectious Disease Serology Test Request (T916) with the specimen.