Sign in →

Test Code CMAMT Chromosomal Microarray, Autopsy/Products of Conception/Stillbirth, Tissue

Useful For

Diagnosis of congenital copy number changes in products of conception, including aneuploidy (ie, trisomy or monosomy) and structural abnormalities

 

Diagnosing chromosomal causes for fetal death

 

Determining recurrence risk of future pregnancy losses

 

Determining the size, precise breakpoints, gene content, and any unappreciated complexity of abnormalities detected previously by other methods such as conventional chromosome and fluorescence in situ hybridization studies

 

Determining if apparently balanced abnormalities identified by previous conventional chromosome studies have cryptic imbalances, since a proportion of such rearrangements that appear balanced at the resolution of a chromosome study are actually unbalanced when analyzed by higher-resolution chromosomal microarray

Testing Algorithm

Hematoxylin and eosin stain review of the paraffin-embedded specimen is performed to identify the area of fetal tissue prior to DNA extraction and microarray analysis.

Method Name

Chromosomal Microarray (CMA)

Reporting Name

Chromosomal Microarray, POC, FFPE

Specimen Type

Varies


Ordering Guidance


If a fresh tissue specimen is submitted, this test will be cancelled and CMAPC / Chromosomal Microarray, Autopsy, Products of Conception, or Stillborn will be added and performed as the appropriate test.

 

For answers to frequently asked questions and more information, see Pregnancy loss on MayoClinicLabs.com.



Additional Testing Requirements


A maternal blood sample is requested when ordering this test; order PPAP / Parental Sample Prep for Prenatal Microarray Testing, Blood under a different order number than the prenatal specimen. Maternal cell contamination testing will be performed at no additional charge on the maternal blood and fetal tissue to rule out the presence of maternal cells in the product of conception sample. Testing will not be rejected if maternal blood is not received; however, the possibility of maternal cell contamination cannot be excluded.

 

A paternal blood sample is desired but not required (see PPAP / Parental Sample Prep for Prenatal Microarray Testing, Blood).



Necessary Information


A reason for testing and pathology report are required in order for testing to be performed. Send information with specimen. Acceptable pathology reports include working drafts, preliminary pathology or surgical pathology reports. The laboratory will not reject testing if this information is not provided, but appropriate testing and interpretation may be compromised or delayed.



Specimen Required


Submit only 1 of the following specimens:

 

Specimen Type: Tissue

Container/Tube: Formalin-fixed, paraffin-embedded block containing fetal or placental (including chorionic villi) tissue.

 

Specimen Type: Slides

Specimen Volume: 6 Consecutive, unstained, 5-micron-thick sections placed on positively charged slides and 1 hematoxylin and eosin-stained slide.


Specimen Minimum Volume

Formalin-fixed, paraffin-embedded tissue block; 5 Consecutive, unstained slides and 1 hematoxylin and eosin-stained slide

Specimen Stability Information

Specimen Type Temperature Time Special Container
Varies Ambient (preferred)
  Refrigerated 

Reject Due To

All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.

Clinical Information

Chromosomal abnormalities may result in malformed fetuses, spontaneous abortions, or neonatal deaths. Estimates of the frequency of chromosome abnormalities in spontaneously aborted fetuses range from 15% to 60%.

 

Chromosomal microarray (CMA) studies of products of conception, a stillborn infant, or a neonate (autopsy) may provide useful information concerning the cause of miscarriage or fetal loss. In addition, CMA may provide information regarding the recurrence risk for future pregnancy loss and risk of having subsequent children with chromosome anomalies. This is particularly useful information if there is a family history of 2 or more miscarriages or when fetal malformations are evident.

 

Chromosomal microarray is a high-resolution method for detecting copy number changes (gains or losses) across the entire genome in a single assay and is sometimes called a molecular karyotype. This CMA test utilizes over 220,000 markers for the detection of copy number changes and regions with absence of heterozygosity. The detection of excess homozygosity on multiple chromosomes may suggest consanguinity. Homozygosity involving the entire genome is indicative of a complete molar pregnancy.

Reference Values

An interpretive report will be provided.

Interpretation

Copy number variants are classified based on known, predicted, or possible pathogenicity and reported with interpretive comments detailing their potential or known significance.

 

While many copy number changes observed by chromosomal microarray testing can readily be characterized as pathogenic or benign, there are limited data available to support definitive classification of a subset into either of these categories, making interpretation of these variants challenging. In these situations, a number of considerations are taken into account to help interpret results including the size and gene content of the imbalance, as well as whether the change is a deletion or duplication. Parental testing may also be necessary to further assess the potential pathogenicity of a copy number change. In such situations, the inheritance pattern and clinical and developmental history of the transmitting parent will be taken into consideration.

 

All copy number variants within the limit of detection classified as pathogenic or likely pathogenic will be reported regardless of size. This includes, but is not limited to, incidental findings currently recommended for reporting by the American College of Medical Genetics and Genomics.(1) Copy number changes with unknown significance will be reported when at least one protein-coding gene is involved in a deletion greater than 1 megabase (Mb) or a duplication greater than 2 Mb.

 

The detection of excessive homozygosity may suggest the need to test for variants in genes associated with autosomal recessive disorders consistent with the patient's clinical presentation that are present in regions of homozygosity. Homozygosity will be reported when involving greater than 20% of the genome. Homozygosity involving the entire genome is indicative of a complete molar pregnancy.

 

The continual discovery of novel copy number variation and published clinical reports means that the interpretation of any given copy number change may evolve with increased scientific understanding.

Day(s) Performed

Monday through Friday

Report Available

21 to 30 days

Specimen Retention Time

Slides and hematoxylin and eosin-stained slide used for analysis are retained by the laboratory. Client provided paraffin blocks and extra unstained slides (if provided) will be returned after testing is complete.

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

81229

LOINC Code Information

Test ID Test Order Name Order LOINC Value
CMAMT Chromosomal Microarray, POC, FFPE 94087-4

 

Result ID Test Result Name Result LOINC Value
44005 Result Summary 50397-9
44006 Result 62356-1
44007 Nomenclature 62356-1
44008 Interpretation 69965-2
44009 Reason for Referral 42349-1
44010 Specimen 31208-2
44011 Source 31208-2
44012 Tissue ID 80398-1
44013 Method 85069-3
44014 Additional Information 48767-8
44016 Released By 18771-6

Forms

1. New York Clients-Informed consent is required. Document on the request form or electronic order that a copy is on file. The following documents are available:

-Informed Consent for Genetic Testing (T576)

-Informed Consent for Genetic Testing-Spanish (T826)

2. Chromosomal Microarray Prenatal and Products of Conception Information (T716)