Sign in →

Test Code FACT Filamentous-Actin (F-actin) Antibody, IgG, Serum

Reporting Name

F-Actin Ab, IgG, S

Useful For

Evaluation of patients with hepatitis of unknown origin associated with hypergammaglobulinemia and/or abnormal liver enzymes

 

This test may also be useful for confirming positivity for smooth muscle antibodies.

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Minimum Volume

0.4 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 21 days
  Frozen  21 days

Reference Values

Negative: <20.0 U

Weak Positive: 20.0-30.0 U

Positive: >30.0 U

Day(s) Performed

Monday

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

83516

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FACT F-Actin Ab, IgG, S 44706-0

 

Result ID Test Result Name Result LOINC Value
FACT F-Actin Ab, IgG, S 44706-0

Clinical Information

Autoimmune hepatitis (AIH) is a chronic disease resulting from immune-mediated liver injury with varied clinical manifestations.(1,2) The precise factors leading to disease initiation and perpetuation are unknown, but likely reflect a combination of genetic predisposition relating to defects in immunological control of autoreactivity, as well as environmental triggers, which precipitate a persistent breakdown in self-tolerance.(2) Initially, patients with AIH may be clinically asymptomatic and are usually identified only through an incidental finding of abnormal liver function tests.(1-4) At a more advanced stage, patients may manifest with symptoms such as jaundice, pruritus, or ascites, which are secondary to the more extensive liver damage. As implied by the name, AIH has many characteristics of an autoimmune disease, including female predominance, hypergammaglobulinemia, association with specific HLA alleles, responsiveness to immunosuppression, and the presence of autoantibodies.(1-3)

 

The clinical features of AIH are nonspecific and can be seen in variety of liver diseases (drug/alcohol-associated hepatitis, viral hepatitis, primary sclerosing cholangitis, etc), the diagnosis can be challenging. A set of diagnostic criteria for AIH has been published and includes the presence of various autoantibodies, elevated total IgG, evidence of hepatitis on liver histology, and absence of viral markers.(1,3,4) Based on the specific autoantibodies present, AIH can be placed into one of three categories.(4) The most prevalent is AIH type 1, linked to the presence of smooth muscle autoantibodies (SMA), antinuclear antibodies (ANA) and perinuclear anti-neutrophil cytoplasmic antibodies. SMA are generally identified by indirect immunofluorescence using a smooth muscle substrate. The antigen specificity of SMA in the context of AIH has been identified as filamentous-actin (F-actin).(3) The combination of autoantibody serology, specifically SMA and anti-F-actin antibodies with liver histology and thorough clinical evaluation are useful in the evaluation of patients with suspected autoimmune hepatitis. SMAs are detected in up to 85% of patients with AIH, either alone or in conjunction with ANA.(1,4,5) The SMA titer can also contribute to International Autoimmune Hepatitis Group diagnostic score in patients with a probable or definite diagnosis of AIH.(1,4,5) These antibodies have also been reported in 33% to 65% of cases of primary biliary cholangitis/AIH overlap syndrome,(6) the concomitant presence of SMA and antimitochondrial antibodies being highly suggestive in this setting.

 

For more information see First-Line Screening for Autoimmune Liver Disease Algorithm.

Interpretation

Positivity for anti-filamentous-actin (F-actin) antibodies may help support a diagnosis of autoimmune hepatitis (AIH) following exclusion of other causes of hepatitis.

 

A negative result for anti-F-actin antibodies does not exclude a diagnosis of AIH.

 

In a study conducted at Mayo Clinic, the F-actin enzyme-linked immunosorbent assay (ELISA) had a clinical sensitivity of 92.9% when using the manufacturer's recommended cutoff of 20.0 U. In addition, the F-actin ELISA had a clinical specificity of 76.7% when using the aforementioned cutoffs. See Supportive Data.

Report Available

2 to 8 days

Specimen Retention Time

14 days

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK
Heat treated specimens Reject

Method Name

Enzyme-Linked Immunosorbent Assay (ELISA)

Testing Algorithm

For more information see First-Line Screening for Autoimmune Liver Disease Algorithm.