Test Code FLUOX Fluoxetine, Serum
Reporting Name
Fluoxetine, SUseful For
Monitoring serum concentration of fluoxetine during therapy
Evaluating potential toxicity
Evaluating patient compliance
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
Serum RedSpecimen Required
Collection Container/Tube: Red top (serum gel/SST are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions:
1. Draw blood immediately before the next scheduled dose (trough).
2. Centrifuge and aliquot serum into plastic vial within 2 hours of collection.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum Red | Refrigerated (preferred) | 28 days | |
Frozen | 28 days | ||
Ambient | 72 hours |
Reference Values
Fluoxetine + Norfluoxetine: 120-500 ng/mL
Day(s) Performed
Wednesday
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
80299
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
FLUOX | Fluoxetine, S | 78437-1 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
80228 | Fluoxetine, S | 74982-0 |
251 | Norfluoxetine, S | 3868-7 |
252 | Fluoxetine+Norfluoxetine | 74948-1 |
Clinical Information
Fluoxetine is a selective serotonin reuptake inhibitor approved for treatment of bulimia, obsessive-compulsive behavior, panic disorders, premenstrual dysphoria, and major depressive disorder, with a variety of off-label uses. Both fluoxetine and its major metabolite, norfluoxetine, are pharmacologically active and are reported together in this assay. Most individuals respond optimally when combined serum concentrations for both parent and metabolite are in the therapeutic range (120-500 ng/mL) at steady state. Due to the long half-life of the parent and metabolite (1-6 days), it may take several weeks for patients to reach steady-state concentrations. Fluoxetine is a potent inhibitor of the metabolic enzyme cytochrome P450 (CYP) 2D6, with lesser inhibitory effects on CYP2C19 and CYP3A. Therapy with fluoxetine is, therefore, subject to numerous drug interactions, which are compounded by wide interindividual variability in fluoxetine pharmacokinetics. Measurement of the drug is useful for managing comedications, dose or formulation changes, and in assessing compliance. Side effects are milder for fluoxetine than for older antidepressants, such as tricyclic antidepressants. The most common side effects of fluoxetine therapy include nausea, nervousness, anxiety, insomnia, and drowsiness. Anticholinergic and cardiovascular side effects are markedly reduced compared to tricyclic antidepressants. Fatalities from fluoxetine overdose are extremely rare.
Interpretation
Most individuals display optimal response to fluoxetine when combined serum levels of fluoxetine and norfluoxetine are between 120 and 500 ng/mL. Some individuals may respond well outside of this range or may display toxicity within the therapeutic range; therefore, interpretation should include clinical evaluation. A toxic range has not been well established.
Report Available
1 to 8 daysSpecimen Retention Time
14 daysReject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Forms
If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.