Test Code HEXP Iohexol, Plasma
Reporting Name
Iohexol, PUseful For
Determining glomerular filtration rate in plasma specimens
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
Plasma HeparinSpecimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Green top (heparin)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot plasma into a plastic vial.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma Heparin | Refrigerated (preferred) | 7 days | |
Frozen | 35 days | ||
Ambient | 7 days |
Reference Values
Not applicable
Day(s) Performed
Monday through Friday
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
82542
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
HEXP | Iohexol, P | 93974-4 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
61713 | Iohexol, P | 93974-4 |
Clinical Information
The assessment of glomerular filtration rate (GFR) is an important parameter of kidney function utilized by clinicians in the care of patients with varying kidney diseases, and for clinical research when precise assessment of kidney function is necessary. The GFR is the sum of all the filtration rates of the individual nephrons within the kidney and, as such, reflects the number of functioning nephrons.
Plasma concentrations of iohexol can be used for measurement of GFR through multiple plasma iohexol determinations following an intravenous bolus injection of iohexol (plasma disappearance) or following a continuous infusion (or subcutaneous injection) of iohexol when used in conjunction with urine iohexol determinations (urinary clearance; HEXU / Iohexol, Timed Collection, Urine).
Interpretation
Low glomerular filtration rate (GFR) values indicate abnormal kidney function, which may be either reversible/transient or irreversible/permanent. GFR tends to decline with age.
Report Available
3 to 4 daysSpecimen Retention Time
7 daysReject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Forms
If not ordering electronically, complete, print, and send a Renal Diagnostics Test Request (T830) with the specimen.